Technical Parameters
Items | Technical Parameters |
Executive Standard | GB25280-2010 |
Working Voltage | AC110V/220V±20% (changed by switch) |
Working Frequency | 47Hz~63Hz |
No-load power | ≤15W |
The whole controller rated load power | 2200W |
Motor operation sequence(special timing state should be statement before production) | all Red(can setup) →green light→green flash can setup) →yellow light→Red light |
Pedestrian signal operation sequence | all Red(can setup) →green light→Green flash(can setup)→Red light |
Rated drive current in each way | 3A |
Surge current in each way | ≥100A |
Maximum independent output channels | 22 |
Maximum independent phase | 8 |
Adjustable menus | 16 |
Can be setup menus number | 30 |
The largest number of each menu | 24 |
The largest number of timers in each day | 24 |
Running time in each step | 1~255 |
Full red transition time | 0~5S |
Yellow light transition time | 1~9S |
Green flashing time | 0~9S |
Operational Temperature Range | -40℃~+80℃ |
Relative Humidity | <95% |
Setting Saving Time(the electricity was cut off) | 10 years |
Time Error | Error/year<2.5 minutes (25±1℃) |